Anadarko E&P Co. LP, HA RA SUS; Comegys 26H, #1, Sec. 26, T20N, R15W, Caddo Pine Island, 14401’ MD 9918’ TVD.

Views: 4059

Replies to This Discussion

Skip, are you basing the "liquids" part on depth, or was there something filed with DNR that indicates this is a liquids well?

Neither.  I'm basing it on previous HA wells drilled in this general area and the Haynesville liquids wells that APC is drilling in Panola and Harrison counties.  Keep in mind that all the wells drilled in the APC North Caddo Haynesville units will be labeled "Haynesville" although the actual producing horizon may be Haynesville, Bossier or Lower Cotton Valley.  The unit depth definitions cover 1500 feet of stratigraphic intervals.  IMO, there is no reason to drill Haynesville horizontal wells at this time in this area, or any other area for that matter, unless APC thought they would recover significant liquid fractions.

Hi Skip - Not sure I understand "all the wells drilled in the APC North Caddo Haynesville units will be labeled "Haynesville" although the actual producing horizon may be Haynesville, Bossier or Lower Cotton Valley."  We have received letters from Anadarko's lawyers over the past months about their applications to unitize on some of our property by dissolving some Smackover units and creating "units for exploration for and production of gas and condensate from the Haynesville Zone, Reservoir A" in Caddo-Pine Island Field, etc.  By your statement above, I take it that these applications might be for lower depths (Bossier or Cotton Valley) rather than Haynesville?  thank you

HGH, each unit application and resulting field order describes a specific stratigraphic interval that is given a name by the applicant.  Therefore all Haynesville units I have ever reviewed included in its depth definition the Bossier Shale.  If an operator drills a Bossier well in that unit, the well is called a Haynesville (HA).  In the early days of the HS PLay a number of operators applied for units with definitions that included the Haynesville and Bossier but also non-shale formations such as the Cotton Valley.  The Commissioner put a stop to that in the Summer of 2008 but those units already approved were allowed to remain in force.  I wrote a blog post about this at the time.  Although the Haynesville definitions granted to APC in North Caddo cover a large interval of rock (~1500') the company has since formed two CV units which overlap two of the 960 acre HA units.  Link to Blog  follows.

http://www.gohaynesvilleshale.com/profiles/blogs/cotton-valley-and-...

Skip, I understand the rig is currently moving in and rigging up on the Comegys 26H.

Thanks, SB.  Bought time.  LOL!

Location built. Waiting on rig.

APC received a permit to drill yesterday.  Looking forward to a spud date.

Any word on a spud date for any of these locations for Anadarko?

Not as of Friday's rig report (3/1/2013).  Keep in mind that these permits are good for one year.

Last I heard was that APC was gonna drill a couple wells around Bryan-College Station and that rig was headed to CPI. They are done with the first well and have spudded the second already. Should be seein the rig in about a month if they have no problems.

Anadarko permits second HA horizontal in Caddo.

WELLS

SERIAL WELL NAME WELL NUM ORG ID FIELD PARISH PROD TYPE SEC TWN RGE EFFECTIVE DATE API NUM
245927 HA RA SU54;VOLENTINE 5-33 H 001 A243 2152 09 00 005 19N 14W 01/31/2013 17017353890000
PRMT DATE SPUD DATE STAT DATE ST CD
01/31/2013 01/31/2013 01

WELL SURFACE COORDINATES

Surface Longitude Surface Latitude Lambert X Lambert Y Ground Elevation Zone Datum
0-0-0 0-0-0 1592145 730655 175.6 N NAD-27

WELL SURFACE COORDINATES GENERATED BY DNR

UTMX 83 UTMY 83 LONGITUDE 83 LATITUDE 83
422598.898111 3614846.51105 -93.8254806 32.66856978

BOTTOM HOLE COORD

EFFECTIVE DATE END DATE PLUGBACK TOTAL DEPTH TRUE VERTICAL DEPTH MEASURED DEPTH LAT DEG LAT MIN LAT SEC LONG DEG LONG MIN LONG SEC COORDINATE SOURCE LAMBERT X LAMBERT Y ZONE COORDINATE SYSTEM
01/31/2013 9862 16695 02 1592203 737601 N 01
01/31/2013 9862 16695 02 2872990 798310 N 02

WELL HISTORY

SERIAL WELL NAME WELL NUM ORG ID FIELD ST CD PT WELL CLASS EFF DATE END DATE STAT DATE
245927 HA RA SU54;VOLENTINE 5-33 H 001 A243 2152 01 00 01/31/2013 01/31/2013

SCOUT INFO

REPORT DATE WELL STATUS MEASURED DEPTH TRUE VERT DEPTH DETAIL
01/31/2013 01 16695 2266' FNL & 529' FWL OF SEC 5. PBHL: 400' FWL & 200' FNL OF SEC 33, T20N-R14W.

PERFORATIONS

RSS

Support GoHaynesvilleShale.com

Not a member? Get our email.

Groups



© 2024   Created by Keith Mauck (Site Publisher).   Powered by