Recent test Information from Sonris shows the Wiley Hunter 29 #H1 Well tested at a rate of 21.5 million cubic feet of gas per day (MMcfd) with a flowing pressure of over 8000 psi. This well is the first super well in T13N-R8W and the second such well in the Martin Field.
EnCana, Wiley Hunter 29 #H1 Well, Serial #241086, S32(29)-T13N-R8W, Red River Parish, 21472 Mcfd, 25/64" Choke, 8347 psi Flowing Pressure
Tags:
Hi Les,
And one "maybe near final" comment/question. I presume that in doing all this drilling into the HS, the producers get a chance to look at BS core samples? (maybe they bother, maybe they don't?). Should they get some additional insight into what they are dealing with in terms of BS potential? For that matter, how much can these guys tell before they drill the lateral in the HS? I would think there would be some indication of the porosity / mineral content / formation depth based on simply drilling the vertical? I am guessing the info is not really enough to decide on continuiing with the lateral; otherwise there would be more "vertical-only" holes scattered around the edges...
Robert, operators do not necessarily core every well but likely would log the interval in the vertical section of the well before building the curve for the horizontal lateral. This should give them some information regarding the Bossier Shale Formation in the Liberty Field area.
Because no horizontal wells in this area have specifically targeted the Bossier Shale for completion, there has not yet been a clear indicator of the commerciality in T12N-R8W. Clearly in some areas there have been excellent wells completed in both formations therefore confirming the "double shale" development opportunity for EnCana and others in those specific areas of the play.
Fascinating reading gentleman, thank you and thanks to the Site Publisher!
Robert, it matters not what the name of the unit is, HOSS, CV, LCV, etc. (although it should). It is the depth interval definition in the application and order that defines what formation(s) are being pooled. As I mention in my Blog, the Commissioner put a stop to including shale intervals in with non-shale intervals in unit applications in the Summer of 2008. Now every time I run across a horizontal "CV" well I look closely at the TVD and add it to my list if I think it is in reality a HA well. Since the Bossier is included in all (?) the Haynesville (HA) Shale depth interval definitions, you will have to look at completion reports on SONRIS Classic to determine if production is from the HA or the BO.
Shale drilling and lithium extraction are seemingly distinct activities, but there is a growing connection between the two as the world moves towards cleaner energy solutions. While shale drilling primarily targets…
ContinuePosted by Keith Mauck (Site Publisher) on November 20, 2024 at 12:40
386 members
27 members
455 members
440 members
400 members
244 members
149 members
358 members
63 members
119 members
© 2024 Created by Keith Mauck (Site Publisher). Powered by
h2 | h2 | h2 |
---|---|---|
AboutAs exciting as this is, we know that we have a responsibility to do this thing correctly. After all, we want the farm to remain a place where the family can gather for another 80 years and beyond. This site was born out of these desires. Before we started this site, googling "shale' brought up little information. Certainly nothing that was useful as we negotiated a lease. Read More |
Links |
Copyright © 2017 GoHaynesvilleShale.com